Influence of several factors on the heterogeneous photocatalytic degradation of phenol

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Pontificia Universidad Católica del Perú

DOI

Acceso al texto completo solo para la Comunidad PUCP

Abstract

Photocatalytic degradation of phenol in aqueous solutions was investigated using heterogeneous photocatalysis with titanium dioxide (TiO2) particles immobilized on the inner wall of an annular upflow reactor. The influence of the concentration of phenol (measured as Dissolved Organic Carbon, DOC) at 15, 50, and 100 mgC L -1, the presence of hydrogen peroxide (H202), two different irradiation sources (germicidal and black light lamps), and two different reactor geometries (reactor 1 with 3,3 cm and reactor 2 with 7,0 cm outer diameters) were evaluated. To further investigate the effect of these parameters, the rate of phenol degradation, the quantum yield, and the energy consumption were calculated. According to the results obtained, the solution with an initial DOC concentration of 100 mgC L -1  in the presence of hydrogen peroxide (242 mmol L -1), using reactor 2 with the germicidal lamp as the photon source, gave the best performance, with degradation rates reaching 36,8 mgC h -1 and with one of the lowest energy consumptions (65 kWh m -3 order 1).
Photocatalytic degradation of phenol in aqueous solutions was investigated using heterogeneous photocatalysis with titanium dioxide (TiO2) particles immobilized on the inner wall of an annular upflow reactor. The influence of the concentration of phenol (measured as Dissolved Organic Carbon, DOC) at 15, 50, and 100 mgC L -1, the presence of hydrogen peroxide (H202), two different irradiation sources (germicidal and black light lamps), and two different reactor geometries (reactor 1 with 3,3 cm and reactor 2 with 7,0 cm outer diameters) were evaluated. To further investigate the effect of these parameters, the rate of phenol degradation, the quantum yield, and the energy consumption were calculated. According to the results obtained, the solution with an initial DOC concentration of 100 mgC L -1 in the presence of hydrogen peroxide (242 mmol L -1), using reactor 2 with the germicidal lamp as the photon source, gave the best performance, with degradation rates reaching 36,8 mgC h -1 and with one of the lowest energy consumptions (65 kWh m -3 order 1).

Description

Keywords

Química

Citation

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as info:eu-repo/semantics/openAccess