Particle detection performance and Geant4 simulation with low-cost CMOS technology

dc.contributor.affiliationPontificia Universidad Católica del Perú. Departamento de Ciencias. Sección Física
dc.contributor.authorBonnett Del Alamo, M.
dc.contributor.authorHelaconde, R.
dc.contributor.authorSoncco, C.
dc.contributor.authorBazo, José
dc.contributor.authorGago, A.M.
dc.date.accessioned2025-07-08T16:33:44Z
dc.date.issued2025-06
dc.description.abstractWe evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using Python and OpenCV libraries. We specify the necessary settings to convert a standard camera into a particle detector sensitive to electrons and photons, including a two-step background filtering procedure. In addition, we implement the first detailed Geant4 simulation that describes the layered geometry and material composition of a commercial CMOS sensor along with the radioactive sources. To enhance the simulation, we include an algorithm for charge diffusion and conversion of the energy deposited by electrons and photons into ADC counts. Our measurements are presented in terms of cluster size, the maximum ADC signal per cluster, and the number of clusters as a function of distance. We find a good agreement between the experimental data and simulation for all these observables and we can reproduce the correlation between cluster size and maximum ADC signal per cluster. Thus this simulation, cross-checked with data, can be used to test the feasibility of further particle detection ideas without the need to implement an experimental setup. However, the sensor has limited primary energy resolution and is thus unable to distinguish between different radioactive sources. Nevertheless, given the accurate measurement of energy deposition, the sensor, once calibrated, is suitable for dosimetric measurements of source activities.en_US
dc.formatapplication/pdf
dc.identifier.doihttps://doi.org/10.1088/1748-0221/20/06/P06004
dc.identifier.urihttp://hdl.handle.net/20.500.14657/203931
dc.language.isoeng
dc.publisherSpringer Naturees_ES
dc.publisher.countryUS
dc.relation.ispartofurn:issn:1748-0221
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0
dc.sourceJournal of instrumentation; Vol. 20, no. 6 (Jun. 2025)es_ES
dc.subjectPartículas (Física nuclear)en_US
dc.subjectDetectoresen_US
dc.subjectCMOS (Electrónica)en_US
dc.subjectFísica--Simulación con computadorasen_US
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#1.03.00
dc.titleParticle detection performance and Geant4 simulation with low-cost CMOS technologyen_US
dc.typeinfo:eu-repo/semantics/article
dc.type.otherArtículo

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bonnett_Del_Alamo_2025_J._Inst._20_P06004.pdf
Size:
1.7 MB
Format:
Adobe Portable Document Format
Description:
Texto completo