Respuesta sísmica de tanques de concreto armado para almacenamiento de agua apoyados sobre un sistema de aislación del tipo péndulo friccional

dc.contributor.advisorFernández-Dávila Gonzales, Victor Iván
dc.contributor.authorMamani Yana, Elvis Jonyes_ES
dc.date.accessioned2017-04-28T17:24:09Zes_ES
dc.date.available2017-04-28T17:24:09Zes_ES
dc.date.created2017es_ES
dc.date.issued2017es_ES
dc.description.abstractLos tanques para almacenamiento de agua son estructuras esenciales y por esta razón es de vital importancia conocer su comportamiento estructural cuando son sometidos a eventos sísmicos severos. Este trabajo muestra las respuestas sísmicas de tanques cilíndricos circulares de Concreto Armado (CA) para almacenamiento de agua apoyados sobre un sistema de aislación del tipo péndulo friccional (FPS, friction pendulum system) bajo solicitación sísmica uni- y bidireccional. Para el análisis sísmico se consideró que el tanque posee comportamiento elástico lineal, además se empleó un modelo mecánico equivalente para representar la interacción tanque-agua, y se utilizó un modelo histerético del tipo bi-axial para representar el comportamiento inelástico no lineal del sistema de aislación. Los parámetros para representar el modelo de análisis son: (H/R) la razón altura del agua-radio interior del tanque, (e/R) la razón espesor de la pared del tanque-radio interior del tanque, (Tb) el período objetivo de vibración del sistema de aislación, y (μb) el coeficiente de fricción del sistema de aislación. Se utilizaron 21 pares de registros del movimiento sísmico del suelo los cuales fueron previamente seleccionados y escaldos. Finalmente, se procedió con el análisis de la respuesta sísmica en el tiempo para estudiar el efecto del movimiento bi-direccional, y los efectos de los parámetros de estudio sobre la respuesta sísmica de tanques de CA para almacenamiento de agua de base aislada. Las respuestas sísmicas del sistema tanque-agua de base aislada muestran una efectividad en la reducción de los valores de la fuerza cortante basal en comparación con su equivalente de base fija del orden de hasta 73% para H/R = 0.5; 83% para H/R = 1.0; y 91% para H/R = 2.0.es_ES
dc.description.abstractWater storage tanks are essential structures and for this reason it is vital to know its structural behavior when they are subjected to severe seismic events. This work shows the seismic response of base-isolated circular cylindrical Reinforced Concrete (RC) water storage tanks with Friction Pendulum System (FPS) under uni- and bi-directional horizontal earthquake ground motions. For the seismic analysis, tanks were considered to have a linear elastic behavior, the tank-water interaction was represented by an equivalent mechanical model, and the inelastic non-linear behavior of the isolation system was represented by a bi-axial hysteretic restoring force model. The parameters of this study are: (H/R) the waterheight/ tank-inner-radius ratio, (e/R) the tank-wall-thickness/tank-inner-radius ratio, (Tb) the target vibration period of the isolation system, and (μb) the friction coefficient of the isolation system. Twenty-one pairs of selected and scaled ground motions were utilized. Time-history analysis was used to study the effect of bidirectional ground motion, as well as the effects of study parameters on seismic response of base-isolated RC water storage tanks. Seismic responses of baseisolated systems, when compared to base-fixed systems, show an effectiveness of FPS isolation system in the reduction of basal shear force values up to 73% for H/R = 0.5; 83% for H/R = 1.0; and 91% for H/R = 2.0.es_ES
dc.description.uriTesises_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12404/8505
dc.language.isospaes_ES
dc.publisherPontificia Universidad Católica del Perúes_ES
dc.publisher.countryPEes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/*
dc.subjectConstrucciones de concreto armado--Efectos sísmicoses_ES
dc.subjectConstrucciones antisísmicases_ES
dc.subjectTanques para agua--Efectos sísmicoses_ES
dc.subjectTanques para agua--Diseño antisísmicoes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.01es_ES
dc.titleRespuesta sísmica de tanques de concreto armado para almacenamiento de agua apoyados sobre un sistema de aislación del tipo péndulo friccionales_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.type.otherTesis de maestría
renati.advisor.dni06303702
renati.discipline732267es_ES
renati.levelhttps://purl.org/pe-repo/renati/level#maestroes_ES
renati.typehttp://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineIngeniería Civiles_ES
thesis.degree.grantorPontificia Universidad Católica del Perú. Escuela de Posgradoes_ES
thesis.degree.levelMaestríaes_ES
thesis.degree.nameMaestro en Ingeniería Civiles_ES

Archivos