Normal human gait patterns in Peruvian individuals: An exploratory assessment using VICON motion capture system

dc.contributor.affiliationPontificia Universidad Católica del Perú. Facultad de Ciencias e Ingeniería
dc.contributor.authorDongo, R.
dc.contributor.authorMoscoso Porras, M.
dc.contributor.authorCallupe, R.
dc.contributor.authorPajaya, J.
dc.contributor.authorElías, D.
dc.date.accessioned2026-03-13T16:58:20Z
dc.date.issued2017
dc.description.abstractGait analysis is of clinical relevance for clinicians. However, normal gait patterns used in foreign literature could be different from local individuals. The aim of this study was to determine the normal gait patterns and parameters of Peruvian individuals in order to have a local referent for clinical assessments and making diagnosis and treatment Peruvian people with lower motor neuron injuries. A descriptive study with 34 subjects was conducted to assess their gait cycle. VICON® cameras were used to capture body movements. For the analyses, we calculated spatiotemporal gait parameters and average angles of displacement of the hip, knee, and ankle joints with their respective 95% confidence intervals. The results showed gait speed was 0.58m/s, cadence was 102.1steps/min, and the angular displacement of the hip, knee and ankle joints were all lower than those described in the literature. In the graphs, gait cycles were close to those reported in previous studies, but the parameters of speed, cadence and angles of displacements are lower than the ones shown in the literature. These results could be used as a better reference pattern in the clinical setting.
dc.description.sponsorshipFunding: This work was supported by the Programa Nacional de Innovación para la Competitividad y Productividad (Innovate Perú), an entity of the Government of Peru, for an Applied Research Grant, grant N° 203-FINCyT-IA-2013. The authors are in debt with all the voluntaries that participate in this project.
dc.identifier.doihttps://doi.org/10.1117/12.2285978
dc.identifier.urihttp://hdl.handle.net/20.500.14657/205855
dc.language.isoeng
dc.publisherSPIE
dc.relation.conferencenameProceedings of SPIE - The InterNational Society for Optical Engineering; Vol. 10572 (2017)
dc.relation.ispartofurn:isbn:978-1-5106-0337-0
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectGait analysis
dc.subjectPeruvian individuals
dc.subjectNormal gait patterns
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.02
dc.titleNormal human gait patterns in Peruvian individuals: An exploratory assessment using VICON motion capture system
dc.typehttp://purl.org/coar/resource_type/c_5794
dc.type.otherComunicación de congreso
dc.type.versionhttps://vocabularies.coar-repositories.org/version_types/c_970fb48d4fbd8a85/

Files

Collections