Surface EMG multichannel array using active dry sensors for forearm signal extraction
| dc.contributor.affiliation | Pontificia Universidad Católica del Perú | |
| dc.contributor.author | Reátegui, J. | |
| dc.contributor.author | Callupe, R. | |
| dc.date.accessioned | 2026-03-13T16:57:52Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | Although superficial electromyographic signals are the most common input signal for machine learning algorithms in hand gesture recognition and finger force estimation applications, there are only a few commercially available systems for superficial EMG acquisition. This work proposes a cheap and easy to fabricate, dry superficial electrodes array. This system uses multiple active differential sensors integrated in a small double layer PCBs, each one uses two small rectangle areas of the bottom layer as conductive layer for signal acquisition. With a differential gain of 60dB between 23 and 3000Hz and a common mode rejection ration of -60dB at 60Hz. Design criteria and simulations are presented. | |
| dc.description.sponsorship | Funding: This work was supported by FONDECYT a branch of the National Council of Science, Technology and Innovación (CONCYTEC), an entity of the Government of Peru, for the project ”Research and Development of Assistive Technologies Applied to Physical Rehabilitatión and Spots Biomechanics with grant 206-2015, DGI PUCP grant ID No 361 and the Mechanical Engineering Sectión of the Pontificia Universidad Católica del Perú. | |
| dc.identifier.doi | https://doi.org/10.1109/INTERCON.2017.8079699 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.14657/205710 | |
| dc.language.iso | eng | |
| dc.publisher | Institute of Electrical and Electronics Engineers | |
| dc.relation.conferencename | Proceedings of the 2017 IEEE 24th InterNational Congress on Electronics, Electrical Engineering and Computing, INTERCON 2017 (2017) | |
| dc.relation.ispartof | urn:isbn:9781509063628 | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Rectangle | |
| dc.subject | SIGNAL (programming language) | |
| dc.subject | Computer science | |
| dc.subject | Common-mode signal | |
| dc.subject | Layer (electronics) | |
| dc.subject | Electronic engineering | |
| dc.subject | Acoustics | |
| dc.subject | Engineering | |
| dc.subject | Computer hardware | |
| dc.subject | Materials science | |
| dc.subject | Analog signal | |
| dc.subject | Mathematics | |
| dc.subject | Digital signal processing | |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#2.02.00 | |
| dc.title | Surface EMG multichannel array using active dry sensors for forearm signal extraction | |
| dc.type | http://purl.org/coar/resource_type/c_5794 | |
| dc.type.other | Comunicación de congreso | |
| dc.type.version | https://vocabularies.coar-repositories.org/version_types/c_970fb48d4fbd8a85/ |
