El Repositorio Digital de Tesis y Trabajos de Investigación PUCP aporta al Repositorio Institucional con todos sus registros, organizados por grado: Doctorado, Maestría, Licenciatura y Bachillerato. Se actualiza permanentemente con las nuevas tesis y trabajos de investigación sustentados y autorizados, así como también con los que que fueron sustentados años atrás.
Ingresa a su web: Repositorio Digital de Tesis y Trabajos de Investigación PUCP

Explorar

Resultados de búsqueda

Mostrando 1 - 5 de 5
  • Ítem
    Design of a counter torque device used in a torque standard machine = Erzeugung des gegendrehmoments in einer drehmoment-normalmesseinrichtung
    (Pontificia Universidad Católica del Perú, 2017-03-09) Pino Samalvides, Eduardo Anibal; Theska, René; Alencastre Miranda, Jorge Hernán; Winter, Simon
    In the last years, the increase in the need of higher accuracy in science, research and technology in precision engineering created an obligation to produce a new torque standard machine for precise measurement of torque. This thesis deals with the design and implementation of a Counter Torque Device which will be used in a new Torque Standard Machine based on moving mass developed in the faculty of precision engineering at the TU Ilmenau. This new Torque Standard Machine must have a measuring range from 1 mNm to 1 Nm and a lower relative uncertainty Ur :S 1x1O-5 (k = 2). In order to achieve this aim, the fundamentals and the state of the art are shown at the beginning of the thesis. After the specific requirements are compiled in a requirements list, then based on physical and technical principles different possible solutions are developed and evaluated, from this evaluation optimal solution is founded, implemented and tested.
  • Ítem
    OMA tests and FEM updating in peruvian archaeological heritage: Chokepukio y modal identification tests on archaeological heritage: the case of Chokepukio
    (Pontificia Universidad Católica del Perú, 2014-09-22) Sovero Ancheyta, Simoné Karim; Martel Cuyubamba, Carol; Aguilar Vélez, Rafael
    modelos numéricos son herramientas útiles para comprender el comportamiento de las estructuras. Sin embargo, contar con un modelo que se ajuste a la realidad es difícil debido a las variables que están en juego y a las simplificaciones que se asumen al construirlo. Para que un modelo sea confiable debe ser calibrado. Esta calibración se realiza comparando ciertos parámetros (por ejemplo las propiedades dinámicas) del comportamiento de la estructura real con los resultados del análisis numérico. Para identificar qué parámetros son los que tienen mayor influencia en el comportamiento de las estructuras es necesario llevar a cabo un análisis de sensibilidad. En este trabajo se presentan dos artículos publicados en congresos internacionales que muestran la calibración del modelo numérico de una estructura histórica ubicada en el sitio arqueológico de Chokepukio (Cusco-Perú). Esta estructura, que data de la época pre-inca (900-1300 dC), es un muro de albañilería de piedra asentada con mortero de barro. Los parámetros modales experimentales de la estructura se obtuvieron llevando a cabo una campaña experimental aplicando la técnica OMA (Operational Modal Analysis). El proceso de calibración se llevó a cabo utilizando un algoritmo de optimización de los parámetros que tenían mayor influencia en la respuesta dinámica de la estructura los cuales fueron identificados a través de un análisis de sensibilidad. El primer artículo titulado “OMA Tests and FEM Updating in Peruvian Archaeological Heritage: Chokepukio” fue presentado en el congreso del EVACES (Experimental Vibration Analysis for Civil Engineering Structures) realizado en la ciudad de Ouro Preto (Brasil, octubre 2013). En este artículo se desarrollaron tres modelos de elementos finitos usando el software SAP2000 y se calibró uno de ellos en base a los parámetros modales obtenidos en la campaña experimental. Los resultados de este trabajo sirvieron como herramienta preliminar para una posterior calibración automática. El segundo artículo titulado “Modal Identification Tests on Archaeological Heritage: The Case of Chokepukio” fue presentado en el congreso del IMAC-XXXII (A Conference and Exposition on Structural Dynamics) realizado en la ciudad de Orlando–Florida (USA, febrero 2014). En este artículo se presentan tres modelos de elementos finitos desarrollados en el software Diana TNO y uno de ellos se calibró en base a los parámetros modales obtenidos en la campaña experimental. Por último, se incluye un anexo que presenta una herramienta, desarrollada en el entorno de MatLab, para llevar a cabo un proceso automático de optimización en base a parámetros modales. Esta optimización se realiza minimizando el error de una función (función objetivo) que depende de las frecuencias y las formas modales de vibración, analíticas y experimentales. La herramienta de optimización automática consta de cinco módulos que incluyen: a) el ingreso de los datos de entrada, b) la resolución de ecuaciones para establecer la función objetivo, c) la aplicación de matrices de ponderación, d) la construcción de la función objetivo y d) el proceso de optimización. En este anexo se incluyen cuatro ejemplos de aplicación de la herramienta propuesta que se presentan según su nivel de complejidad, desde una viga con un solo parámetro de calibración hasta una estructura real con cuatro parámetros de calibración.
  • Ítem
    Software for calibrating a digital image processing
    (Pontificia Universidad Católica del Perú, 2014-05-30) Lang, Kathrin; Madrid Ruiz, Ericka Patricia; Schale, Florian
    This work is about learning tool wich provides the necessary parameters for a program controlling robots of type LUKAS at the Faculty of Mechanical Engineering. The robot controlling program needs various parameters depending on its environment, like the light intensity distribution, and camera settings as exposure time and gain raw. These values have to be transmitted from the learning tool to the robot controlling software. Chapter one introduces the robots of type LUKAS which are created for the RoboCup Small Size League. Furthermore, it introduces the camera used for image processing. The second chapter explains the learning process according to Christoph UBfeller and deduces the requirements for this work. In the third chapter theoretical basics concerning image processing, wich are fundamental for this work, are explained. Chapter 4 describes the developed learning tool which is used for the learning process and generates the required parameters for the robot controlling software. In chapter five practical test with two persons are represented. The sixth and last chapter summarizes the results.
  • Ítem
    Estudio de las causas de pérdida de calibración de equipos de terapia con ultrasonido utilizados en rehabilitación
    (Pontificia Universidad Católica del Perú, 2013-11-29) Aguila Gonzales, Anthony Richard del; Toledo Ponce, Eduardo
    Actualmente el ultrasonido es una técnica de rehabilitación muy usada en distintos lugares del mundo para tratar personas que han sufrido algún tipo de lesión tisular. Este tipo de terapia ha ganado prestigio debido a la practicidad de su uso y por sus buenos resultados a causa de los efectos mecánicos (micromasaje) y térmicos que estimulan el metabolismo y la reparación de los tejidos afectados. Sin embargo, estos equipos tienen una desventaja: en algunas ocasiones pierden la calibración sin tener mucho tiempo de uso, esto quiere decir que los equipos pueden emitir una potencia mayor, originando que el paciente tenga algunas molestias o pueda sufrir una leve quemadura; o una potencia menor, lo cual no generaría el calor necesario para que se realice la rehabilitación con éxito. En el presente estudio se analizan equipos de ultrasonido analógicos en vez de equipos digitales, esto se debe a que en esta clase de equipos, las etapas son muy parecidas, con lo cual se puede generalizar el estudio para varios equipos. Primero se analiza el diagrama de bloques del equipo de ultrasonido, se eligen las etapas que van a ser estudiadas teniendo como criterio si éstas tienen relación directa con la señal de salida o no. Luego por cada etapa se elige un elemento crítico el cual es el más importante dentro del circuito y el más susceptible a error. A continuación se prueban los circuitos funcionando correctamente y luego se prueban con variaciones las cuales dependen del elemento crítico elegido. Por último se concluye si la etapa analizada puede influir en la potencia de salida del equipo y por ende llevarlo a perder la calibración. Según el estudio realizado, las etapas de oscilación, digitalización y amplificación pueden llevar a la pérdida de calibración del equipo; la etapa de Modo Pulsado no influye en la pérdida de calibración; sin embargo, una falla en esta etapa puede perjudicar al paciente si se le trata con una intensidad mayor a la recomendada. En el transductor se encontraron fallas principalmente mecánicas y también fallas causadas por mala manipulación del usuario.
  • Ítem
    Protocolo de calibración de la concentración parcial de oxígeno en ventiladores pulmonares
    (Pontificia Universidad Católica del Perú, 2011-09-02) Mendoza Barrenechea, Saúl Enrique; Callupe Pérez, Rocío Liliana
    Actualmente en el Perú, a diferencia de otros países latinoamericanos, los centros de salud no cuentan con un Sistema de Mantenimiento Preventivo de sus equipos médicos. La calibración de equipos médicos no es una práctica frecuente ni obligatoria ya que se carece de un marco legal que exija el cumplimiento de normas internacionales de mantenimiento y calibración. El mantenimiento continuo de estos equipos es fundamental ya que, en muchos casos, sirven para mantener con vida a un ser humano. Dentro de este grupo de equipos médicos críticos se encuentra el ventilador pulmonar, que como se explicará más adelante es empleado para proveer de soporte respiratorio a pacientes que no puedan asumir la función natural de respiración. Más aún, los que trabajan en UCI (Unidad de Cuidados Intensivos) toman control completo de esta tarea, es decir, del correcto funcionamiento del ventilador depende la vida del paciente. Entonces es indispensable que un dispositivo como éste se encuentre en perfecto estado, y esto sólo se logra realizando un mantenimiento tanto preventivo como correctivo a lo largo de la vida útil del equipo. Sin embargo, la implementación de un sistema de mantenimiento y calibración se haya suscrito dentro de limitaciones tales como los recursos económicos con que cuente el centro de salud, la disponibilidad del personal técnico calificado, entre otras cosas. El presente trabajo de investigación pretende aportar a la problemática descrita con el diseño de un protocolo de calibración del parámetro de FiO2 en el ventilador pulmonar; para realizar las pruebas correspondientes se cuenta con el analizador de oxígeno, el cual será usado como instrumento de medición. La norma IEC 60601-2-12 “Requisitos particulares para la seguridad de los ventiladores pulmonares” ha sido aplicada al desarrollo de este documento para proveerlo de un marco normativo internacional. Todas las pruebas y ensayos descritos en este documento fueron desarrollados en el Hospital Dos de Mayo con la colaboración del Departamento de Mantenimiento de Equipos Médicos y la Unidad de Cuidados Intensivos de dicha institución.